Replace the floor temperature probe
Replace the floor temperature probe
The manual (p. 68). First check the plug is pushed fully onto its pins behind the display: a loose plug also shows ErS.
- Let the oven go cold and disconnect the gas.
- Slide the thermometer display out.
- Unscrew the probe from the roof of the dock, under the stone, with a 10 mm spanner.
- Screw the new probe into the same place.
- Plug its cable into the thermometer board. For more room, take off the rear dock panel.
- Refit the display, switch on and check the floor reading shows with no ErS.